Anemometers

We are a leading Manufacturer of wind transmitter first class advanced, meteowind 2 wind sensor, wind transmitter first class advanced ii, mw 35 anemometer, anemometer pce-wsac 50w 24 and hd53ls to series high sensitivity anemometer for very low wind speeds from Noida, India.

Wind Transmitter First Class Advanced

  • Wind Transmitter First Class Advanced
  • Wind Transmitter First Class Advanced
  • Wind Transmitter First Class Advanced
Wind Transmitter First Class Advanced
Get Best Quote
Rs 90,000  / PiecePrice on Request

Product Brochure

Mounting optionsPole Mount
Usage/ApplicationIndustrial
Model Name/Number4.3351.00.000
MaterialSS
Resolution0.05m wind run
Accuracy0.3...50m/s 1% of meas. value or < 0.2m/s
Starting velocity< 0.3m/s
Before operating with or at the device/product, read through the operating instructions.This manual contains instructions which should be followed on mounting, start-up, and operation.A non-observance might cause:- failure of important functions- endangerment of persons by electrical or mechanical effect- damage to objects• Mounting, electrical connection and wiring of the device/product must be carried out only by a qualifiedtechnician who is familiar with and observes the engineering regulations, provisions and standardsapplicable in each case.• Repairs and maintenance may only be carried out by trained staff or Adolf Thies GmbH & Co. KG.Only components and spare parts supplied and/or recommended by Adolf Thies GmbH & Co. KGshould be used for repairs.• Electrical devices/products must be mounted and wired only in a voltage-free state.• Adolf Thies GmbH & Co KG guarantees proper functioning of the device/products provided that nomodifications have been made to the mechanics, electronics or software, and that the following pointsare observed:• All information, warnings and instructions for use included in these operating instructions must betaken into account and observed as this is essential to ensure trouble-free operation and a safecondition of the measuring system / device / product.• The device / product is designed for a specific application as described in these operating instructions.• The device / product should be operated with the accessories and consumables supplied and/orrecommended by Adolf Thies GmbH & Co KG.• Recommendation: As it is possible that each measuring system / device / product may, under certainconditions, and in rare cases, may also output erroneous measuring values, it is recommended usingredundant systems with plausibility checks for security-relevant applications.

View Complete details

Yes! I am Interested Request a call back

MeteoWind 2 Wind Sensor

  • MeteoWind 2 Wind Sensor
  • MeteoWind 2 Wind Sensor
  • MeteoWind 2 Wind Sensor
MeteoWind 2 Wind Sensor
Get Best Quote
Rs 60,000  / PiecePrice on Request

Product Brochure

Mounting optionsTower Mount
Usage/ApplicationIndustrial
LinearityR2 > 0.99995 MEASNET/IEC 61400-12-1:2005
Tilt angle sensitivityCosine response, see graph. (Horizontal wind speed measurement)
Starting wind speed<0.3m/s
Distance constant (Delay distance)<3m (est.) (per ASTM D 5096-96)
Anemometer with a wind vane. Exceeds WMOand MEASNET Class 1 accuracy standards formeteorology & wind resource assessment. Very low4mA combined power consumption and integratedtriple layer lightning & surge protection for reliableoperation. Protected oversize bearings with high dirtand weather resistance proven to provide long-termmeasurement stability & reliability in dirty & dustyenvironments.

View Complete details

Yes! I am Interested Request a call back

Wind Transmitter First Class Advanced

  • Wind Transmitter First Class Advanced
  • Wind Transmitter First Class Advanced
  • Wind Transmitter First Class Advanced
  • Wind Transmitter First Class Advanced
Wind Transmitter First Class Advanced
Get Best Quote
Rs 90,000  / PiecePrice on Request

Product Brochure

Sensor TypeCapacitive
Mounting optionsPole Mount
Usage/ApplicationIndustrial
Model Name/Number4.3352.00.400
ColorGrey,Black
MaterialSS
Accessreading / writing
Initial value1
Before operating with or at the device/product, read through the operating instructions.This manual contains instructions which should be followed on mounting, start-up, and operation.A non-observance might cause:- failure of important functions- endangerment of persons by electrical or mechanical effect- damage to objects• Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified
technician who is familiar with and observes the engineering regulations, provisions and standards ap-plicable in each case.
• Repairs and maintenance may only be carried out by trained staff or Adolf Thies GmbH & Co. KG.Only components and spare parts supplied and/or recommended by Adolf Thies GmbH & Co. KGshould be used for repairs.• Electrical devices/products must be mounted and wired only in a voltage-free state.• Adolf Thies GmbH & Co KG guarantees proper functioning of the device/products provided that nomodifications have been made to the mechanics, electronics or software, and that the following pointsare observed:• All information, warnings and instructions for use included in these operating instructions must be
taken into account and observed as this is essential to ensure trouble-free operation and a safe condi-tion of the measuring system / device / product.
• The device / product is designed for a specific application as described in these operating instructions.
• The device / product should be operated with the accessories and consumables supplied and/or rec-ommended by Adolf Thies GmbH & Co KG .
• Recommendation: As it is possible that each measuring system / device / product may, under certainconditions, and in rare cases, may also output erroneous measuring values, it is recommended usingredundant systems with plausibility checks for security-relevant applications.

View Complete details

Yes! I am Interested Request a call back

Wind Transmitter First Class Advanced II

  • Wind Transmitter First Class Advanced II
  • Wind Transmitter First Class Advanced II
  • Wind Transmitter First Class Advanced II
  • Wind Transmitter First Class Advanced II
  • Wind Transmitter First Class Advanced II
Wind Transmitter First Class Advanced II
Get Best Quote
Price on Request

Product Brochure

Sensor TypeInductive
Mounting optionsPole Mount
Usage/ApplicationIndustrial
Resolution0.05m wind run
MaterialSS
Measuring range0.3 ... 75m/s
Survival speed80 m/s (min. 30 minutes)
Before operating with or at the device/product, read through the operating instructions.This manual contains instructions which should be followed on mounting, start-up, and operation.A non-observance might cause:- failure of important functions- endangerment of persons by electrical or mechanical effect- damage to objects
• Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified techni-cian who is familiar with and observes the engineering regulations, provisions and standards applicable in
each case.
• Repairs and maintenance may only be carried out by trained staff or Adolf Thies GmbH & Co. KG. Only com-ponents and spare parts supplied and/or recommended by Adolf Thies GmbH & Co. KG should be used for
repairs.• Electrical devices/products must be mounted and wired only in a voltage-free state.
• Adolf Thies GmbH & Co KG guarantees proper functioning of the device/products provided that no modifica-tions have been made to the mechanics, electronics or software, and that the following points are observed:
• All information, warnings and instructions for use included in these operating instructions must be taken into
account and observed as this is essential to ensure trouble-free operation and a safe condition of the measur-ing system / device / product.
• The device / product is designed for a specific application as described in these operating instructions.
• The device / product should be operated with the accessories and consumables supplied and/or recom-mended by Adolf Thies GmbH & Co KG .
• Recommendation: As it is possible that each measuring system / device / product may,under certain condi-tions, and in rare cases, may also output erroneous measuring values, it is recommended using redundant
systems with plausibility checks for security-relevant applications.

View Complete details

Yes! I am Interested Request a call back

MW 35 Anemometer

  • MW 35 Anemometer
  • MW 35 Anemometer
  • MW 35 Anemometer
MW 35 Anemometer
Get Best Quote
Price on Request

Product Brochure

Usage/ApplicationIndustrial
Model Name/NumberMW 35
Operating Range0 - 75 m/s
Starting Speed< 0.8 m/s
Maximum Wind Load80 m/s
Analogue0 - 10 V @ 0-40 m/s
SerialRS-485 NMEA 0183
Wind is the flow of air and other gasses in the atmosphere.When a difference in pressure exists between two adjacentair masses, the air tends to flow from the region of highpressure to the region of low pressure. The speed anddirection of the wind are important parameters in the dailymeteorological observations used in weather forecasts andin the control of industrial processes. Industries such asrenewable energy, transportation and environment requireaccurate and reliable measurement of wind speed and winddirection.
A set of wind sensors comprises an anemometer to measurethe speed and a wind vane to measure the direction. MierijMeteo has over 25 years of experience in the development andmanufacturing of anemometers and wind vanes according tothe requirements of the World Meteorological Organization(WMO). All our wind sensors have passed comprehensivetesting and calibration in our wind tunnel and wind vanecalibrator.
Our industrial wind sensors have been tested under extremeenvironmental conditions (from arctic to desert climates).The embedded heater will keep the sensors ice-free attemperatures down to at least -40 °C and construction isshock and vibration proof. Another important feature is thespecial design to protect the bearings from dust and dirt.This ensures a long, maintenance-free, operating life.

View Complete details

Yes! I am Interested Request a call back

Anemometer PCE-WSAC 50W 24

  • Anemometer PCE-WSAC 50W 24
  • Anemometer PCE-WSAC 50W 24
  • Anemometer PCE-WSAC 50W 24
  • Anemometer PCE-WSAC 50W 24
Anemometer PCE-WSAC 50W 24
Get Best Quote
Price on Request

Product Brochure

Display TypeDigital
Usage/ApplicationIndustrial
Model Name/NumberPCE-WSAC 50W 24
Power supply for sensors+15V DC
EntrancePulse, analog (4 ... 20-mA) or radio
RadioIEEE 802.15.4 ISM 2.4 GHz
Unitskm / h, mph, m / s
The anemometer PCE-WSAC 50W is primarily used to measure and monitor the wind load on cranes or wind turbines. Furthermore, the windsituation can be measured and analyzed before commissioning a wind turbine. The anemometer PCE-WSAC 50W is equipped with alarm relayfor a pre-alarm or main alarm.
Due to the high measuring range of up to 50 m / s of the anemometer, stormy gusts can also be monitored. The radio range ofthe anemometer is in the open field up to 750 m / 2500 ft in the free frequency band of 2.4 GHz. When installing the display of the wind alarmPCE-WSAC 50W in buildings, a range of up to 60 m / 200 ft can be achieved for the wind sensor. Due to the integrated 4 ... 20-mA analogueoutput of the wind alarm display, the measured data can also be transferred to other controllers for evaluation.

View Complete details

Yes! I am Interested Request a call back

HD53LS to Series High Sensitivity Anemometer for Very Low Wind Speeds

  • HD53LS to Series  High Sensitivity Anemometer for Very Low Wind Speeds
  • HD53LS to Series  High Sensitivity Anemometer for Very Low Wind Speeds
  • HD53LS to Series  High Sensitivity Anemometer for Very Low Wind Speeds
  • HD53LS to Series  High Sensitivity Anemometer for Very Low Wind Speeds
HD53LS to Series  High Sensitivity Anemometer for Very Low Wind Speeds
Get Best Quote
Price on Request

Product Brochure

Usage/ApplicationIndustrial
Model Name/NumberHD53LS 2-AXIS ULTRASONIC ANEMOMETER
Accuracy+- 0.2 m/s or +- 2%, the greatest
Range0 to 50 m/s
SensorsMODBUS
Temperature-20 to +55 DegreeC

HD53LS is a 2-axis ultrasonic static anemometer for measuring:

  • Wind speed and direction, U-V Cartesian components of wind speed.
  • Wind Gust (only in version with RS485 MODBUS-RTU output).

The average of wind speed and direction over a period configurable up to 10 minutes is calculated.

Two versions are available:

  • HD53LS.A: with two analog outputs (one for wind speed and one for wind direction), factory configurable among 4…20 mA (standard), 0…1 V, 0…5 V, 0…10 V (to be specified when ordering).
  • HD53LS.S: with RS485 MODBUS-RTU output.

Advantages of the HD53LS series:

  • The absence of moving parts minimizes maintenance.
  • High sensitivity for detecting very low speeds, which are not detectable by traditional methods.
  • Fast and easy installation (on ∅ 40 mm mast, optional tripod available).
  • The low power of the instrument allows installation in remote sites, with power from solar panel and battery.
  • The version with RS485 MODBUS-RTU output allows instrument networking.

View Complete details

Yes! I am Interested Request a call back

Wind Transmitter First Class Advanced II

  • Wind Transmitter First Class Advanced II
  • Wind Transmitter First Class Advanced II
  • Wind Transmitter First Class Advanced II
  • Wind Transmitter First Class Advanced II
  • Wind Transmitter First Class Advanced II
Wind Transmitter First Class Advanced II
Get Best Quote
Price on Request

Product Brochure

Usage/ApplicationIndustrial
Resolution0.05m wind run
ColorGrey
Measuring range0.3 ... 75m/s
Measurement uncertainty+-1% from the measured value or < +-0,2m/s @ 0,3 ... 50m/s
Survival speed80 m/s (min. 30 minutes)
Distance constant< 3m (acc. to ASTM D 5096 - 96) 3m acc. to ISO 17713-1
Before operating with or at the device/product, read through the operating instructions.This manual contains instructions which should be followed on mounting, start-up, and operation.A non-observance might cause:- failure of important functions- endangerment of persons by electrical or mechanical effect- damage to objects
• Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified techni-cian who is familiar with and observes the engineering regulations, provisions and standards applicable in
each case.
• Repairs and maintenance may only be carried out by trained staff or Adolf Thies GmbH & Co. KG. Only com-ponents and spare parts supplied and/or recommended by Adolf Thies GmbH & Co. KG should be used for
repairs.• Electrical devices/products must be mounted and wired only in a voltage-free state.
• Adolf Thies GmbH & Co KG guarantees proper functioning of the device/products provided that no modifica-tions have been made to the mechanics, electronics or software, and that the following points are observed:
• All information, warnings and instructions for use included in these operating instructions must be taken into
account and observed as this is essential to ensure trouble-free operation and a safe condition of the measur-ing system / device / product.
• The device / product is designed for a specific application as described in these operating instructions.
• The device / product should be operated with the accessories and consumables supplied and/or recom-mended by Adolf Thies GmbH & Co KG .
• Recommendation: As it is possible that each measuring system / device / product may,under certain condi-tions, and in rare cases, may also output erroneous measuring values, it is recommended using redundant
systems with plausibility checks for security-relevant applications.

View Complete details

Yes! I am Interested Request a call back

05103 High Performance Wind Sensor

  • 05103 High Performance Wind Sensor
  • 05103 High Performance Wind Sensor
05103 High Performance Wind Sensor
Get Best Quote
Price on Request
Mounting optionsPole Mount
Usage/ApplicationIndustrial
BrandYoung
Model Name/Number05103
Range0 to 100 m/s (224 mph)
Pitch29.4 cm air passage per revolution
Distance Constant2.7 m (8.9 ft.) for 63% recovery
Threshold Sensitivity1.0 m/s (2.2 mph)
The wind speed sensor is a four bladehelicoid propeller. Propeller rotation producesan AC sine wave voltage signal with frequencydirectly proportional to wind speed. Slip rings andbrushes are eliminated for increased reliability.The wind direction sensor is a rugged yetlightweight vane with a sufficiently low aspectratio to assure good fidelity in fluctuating windconditions. Vane angle is sensed by a precisionpotentiometer housed in a sealed chamber. With a known excitation voltage applied to thepotentiometer, the output voltage is directly proportional to vane angle. A mounting orientationring assures correct realignment of the wind direction reference when the instrument is removedfor maintenance.

View Complete details

Yes! I am Interested Request a call back

Anemometer Young Propeller For vertical measurements CFT Propeller 27106T

Anemometer Young Propeller For vertical measurements CFT Propeller 27106T
Get Best Quote
Price on Request

Product Brochure

Usage/ApplicationIndustrial
Model Name/Number27106T
Accuracy+- 1% (0.0049 m/s per rpm)
BrandAmmonit
Slope18 m/s/V
Output voltageAnalog DC voltage proportional to axial wind component. Polarity reverses with reverse rotation. 18
Threshold sensitivity0.4 m/s
The Propeller Anemometer is a precision, single axis wind measuring instrument. The anemometer utilizes afast response helicoid propeller and high quality tach-generator transducer to produce a DC voltage that islinearly proportional to air velocity.Airflow from any direction may be measured, however, the propeller responds only to the component of theair flow which is parallel to its axis of rotation. Off-axis response closely approximates a cosine curve withappropriate polarity; with perpendicular air flow, the propeller does not rotate.The output signal is suitable for a wide range of signal translators and data logging devices. The Model 27106Twith carbon fiber thermoplastic (CFT) propeller offers high sensitivity and durability.

View Complete details

Yes! I am Interested Request a call back

Anemometer Windspeed (Vector) A100LM/PC3

Anemometer Windspeed (Vector) A100LM/PC3
Get Best Quote
Price on Request

Product Brochure

Usage/ApplicationIndustrial
Model Name/NumberS14100
BrandAmmonit
Resolution0.05 m/s
Starting wind speed0.2 m/s
Distance constant2.3 m +- 10 %
Classified according to IEC standard“Low Power”, high frequency output signalRange 0.2 ... 75 m/sResolution < 0.5 m/sLow power, pulse output onlyConsumes 1 mA while operating from the logger’s battery supply.Measurement principleThe low-inertia 3-cup rotor is set into rotation by the wind. The wheel is scanned optoelectronically and themeasuring value is available at the output as a digital signal.

View Complete details

Yes! I am Interested Request a call back

Wind Transmitter First Class Advanced

Wind Transmitter First Class Advanced
Get Best Quote
Price on Request

Product Brochure

Sensor TypeCapacitive
Mounting optionsPole Mount
Usage/ApplicationIndustrial
Model Name/Number4.3352.10.400
ColorSilver
MaterialSS
Before operating with or at the device/product, read through the operating instructions.This manual contains instructions which should be followed on mounting, start-up, and operation.A non-observance might cause:- failure of important functions- endangerment of persons by electrical or mechanical effect- damage to objects• Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified
technician who is familiar with and observes the engineering regulations, provisions and standards ap-plicable in each case.
• Repairs and maintenance may only be carried out by trained staff or Adolf Thies GmbH & Co. KG.Only components and spare parts supplied and/or recommended by Adolf Thies GmbH & Co. KGshould be used for repairs.• Electrical devices/products must be mounted and wired only in a voltage-free state.• Adolf Thies GmbH & Co KG guarantees proper functioning of the device/products provided that nomodifications have been made to the mechanics, electronics or software, and that the following pointsare observed:• All information, warnings and instructions for use included in these operating instructions must be
taken into account and observed as this is essential to ensure trouble-free operation and a safe condi-tion of the measuring system / device / product.
• The device / product is designed for a specific application as described in these operating instructions.
• The device / product should be operated with the accessories and consumables supplied and/or rec-ommended by Adolf Thies GmbH & Co KG .
• Recommendation: As it is possible that each measuring system / device / product may, under certainconditions, and in rare cases, may also output erroneous measuring values, it is recommended usingredundant systems with plausibility checks for security-relevant applications.

View Complete details

Yes! I am Interested Request a call back

27106dt Gill Propeller Anemometer

27106dt Gill Propeller Anemometer
Get Best Quote
Price on Request
Usage/ApplicationAir Velocity
Model Name/Number27106DTRange:
Range0 to 35 m/s (80 mph)
Sensors20 cm diameter 4-blade helicoid propeller molded of carbon fiber thermoplastic
BrandYoung
Pitch30.0 cm air passage per revolution
Power Requirement10-14 VDC (12mA @ 12 VDC)
The Gill Propeller Anemometer Photochopper is a low thresholdprecision air velocity sensor employing a fast response helicoidpropeller. The instrument uses a high quality optical photo chopperwhich converts propeller rotation to a square wave signal whosefrequency is linearly proportional to air velocity. The output signalis the same regardless of propeller rotation. For applicationswhere propeller rotation in two directions is required, the model27106F is offered.Airflow from any direction may be measured, however, the propellerresponds only to the component of the air flow which is parallel to theaxis of its rotation. Off-axis response closely approximates a cosinecurve (see accompanying graphs) with appropriate polarity. Withperpendicular air flow the propeller does not rotate.The instrument mounts to 3/4 inch standard pipe. A rugged cableconnector provides both electrical and mechanical connection. Adust cap is provided to protect the connector when the instrumentis removed.

View Complete details

Yes! I am Interested Request a call back

27106t Gill Propeller Anemometer

27106t Gill Propeller Anemometer
Get Best Quote
Price on Request
Usage/ApplicationLaboratory
Model Name/Number27106t
Range0 to 35 m/s (80 mph)
Temperature-50 to 50 DegreeC (-58 to 122 DegreeF)
Pitch30.0 cm air passage per revolution
Propeller20cm 4-blade Carbon Fiber Thermoplastic (CFT) helicoid propeller
The Gill Propeller Anemometer is a low threshold precision airvelocity sensor employing a fast response helicoid propeller. Theinstrument uses a high quality tach-generator transducer whichconverts propeller rotation to a DC voltage that is linearly proportionalto air velocity. The output signal is suitable for a wide range of signaltranslators and data logging devices.Airflow from any direction may be measured, however, the propellerresponds only to the component of the air flow which is parallel to theaxis of its rotation. Off-axis response closely approximates a cosinecurve (see accompanying graphs) with appropriate polarity. Withperpendicular air flow the propeller does not rotate.For detailed studies of low air speeds, optional propeller shaftextensions improve response in the 90° stall region by improvingsymmetry and reducing the stall angle.The instrument mounts to 3/4 inch standard pipe. A rugged cableconnector provides both electrical and mechanical connection. Adust cap is provided to protect the connector when the instrumentis removed.

View Complete details

Yes! I am Interested Request a call back

Meteo Wind Compact Anemometer

  • Meteo Wind Compact Anemometer
  • Meteo Wind Compact Anemometer
  • Meteo Wind Compact Anemometer
Meteo Wind Compact Anemometer
Get Best Quote
Rs 70,000  / PiecePrice on Request

Product Brochure

Sensor TypeMagnetic
Mounting optionsTower Mount
Usage/ApplicationIndustrial
Supply Voltage3.2 V...15 VDC reverse polarity protection
LinearityR2 > 0.99995
Starting wind speed<0.2 m/s
Distance constant (Delay distance)< 1m (est.) (per ASTM D 5096-96)
Compact anemometer and wind direction vane sensor with ultra-low power, lightningprotection & no dead spot.Meets all WMO measurement standards.Designed for wireless AWOS, IoT LoRaWAN, IoT Sigfox and NB-IoT weather stations.Elliptical cup design offers superb aerodynamics in a compact and cost-effectivepackage of anodized aluminum suitable for most environments.Superb dirt and weather resistance for long-term wind measurement stability &reliability in all environments.

View Complete details

Yes! I am Interested Request a call back

S12100H Anemometer Thies Compact

  • S12100H Anemometer Thies Compact
  • S12100H Anemometer Thies Compact
  • S12100H Anemometer Thies Compact
  • S12100H Anemometer Thies Compact
  • S12100H Anemometer Thies Compact
  • S12100H Anemometer Thies Compact
  • S12100H Anemometer Thies Compact
  • S12100H Anemometer Thies Compact
  • S12100H Anemometer Thies Compact
  • S12100H Anemometer Thies Compact
S12100H Anemometer Thies Compact
Get Best Quote
Price on Request

Product Brochure

Usage/ApplicationLaboratory
Model Name/NumberS12100H
Electrical supply for heating24V AC/DC 20W
Weight0.7 Kg
ProtectionIP 55
Type of ball bearingsMetallic ball bearings
Resolution< 0.1 m/s
The cup star is set into rotation by the wind. An opto-electronic speed scan-ning produces a frequency, which is, proportional to the wind speed, available
as output signal. The anemometer is equipped with an electronically regulatedheating system in order to prevent ice from the bearings.

View Complete details

Yes! I am Interested Request a call back

Anemometer Vaisala WAA252

  • Anemometer Vaisala WAA252
  • Anemometer Vaisala WAA252
  • Anemometer Vaisala WAA252
Anemometer Vaisala WAA252
Get Best Quote
Price on Request

Product Brochure

Usage/ApplicationIndustrial
Model Name/NumberWAA252
BrandAmmonit
Starting threshold< 0.5 m/s
Distance constant2.7 m
Accuracy with transfer function UF 0 0.1 x R-0.3 / 1.0 m/s
Input power24 VDC +- 10%, 3.2 A max.
The WAA252 Heated Anemometer is an optimum choice, when a non-freezing gauge is required. It offers the linearity and sensitivity of a well-designed cup anemometer plus the advantage of heating carried out right
where it is needed - in the cups. Foil heaters are inserted in each cup and inthe cup wheel hub. For easy maintenance the cup assembly is removable,with a 2-pin connector for heating electricity.The transmission of heating power to the WAA252’s rotor is contactless,with no slip rings or brushes. This feature completely eliminates sparksand excessive friction or wear. Power to the heaters is supplied via a rotarytransformer, with 26 kHz low-EMI sine wave. An intelligent heating controlcircuitry is included with integral sensors for both ambient and internal
temperature. Therefore, there is no need for a separate temperature sen-sor in the system. Power consumption, typically 72 watts, is very low con-sidering the heating efficiency and the protection against freezing provided.
Approximately 50 watts of the power is on the cup wheel, 12 watts on theshaft and bearings, and 10 watts on the body. Hence also the sensor body
is kept free of ice, which is important for maintaining the gauge’s aerody-namic performance.

View Complete details

Yes! I am Interested Request a call back

Wind Transmitter Compact

  • Wind Transmitter Compact
  • Wind Transmitter Compact
  • Wind Transmitter Compact
Wind Transmitter Compact
Get Best Quote
Price on Request

Product Brochure

Usage/ApplicationIndustrial
Model Name/Number4.3520.10.000
Accuracy+-3 % of meas. value or +- 0.5 m/s
Measuring range0.5 ... 50 m/s
Resolution< 0.1 m/s
Frequency2 ... 573 Hz
Current consumption20 mA
Part number: 4.3520.10.000Measuring transmitter for the measurement of the horizontal wind velocity with frequency output(active signal). Suitable for data loggers.The cup-star consists of plastic, the housing is made of anodised aluminium and plastic. Theinstrument has a threaded pin PG 21 with 2 nuts for mounting.

View Complete details

Yes! I am Interested Request a call back

P2546-OPR Cup Anemometer

  • P2546-OPR Cup Anemometer
  • P2546-OPR Cup Anemometer
  • P2546-OPR Cup Anemometer
P2546-OPR Cup Anemometer
Get Best Quote
Price on Request

Product Brochure

Usage/ApplicationIndustrial
Model Name/NumberP2546-OPR
Sensors3-cup anemometer
CalibrationU = 0.620 x f + 0.217 [m/s]
Distance constant (63% recovery)1.81 +- 0.04 m
Starting threshold< 0.3 m/s
The WindSensor P2546-OPRCup Anemometer combinesunrivaled performance with theonly IEC 61400-12-1 compliantclassification on the market.
WindSensor
windsensor.com
WindSensor P2546-OPR is the highest-perform-ing cup anemometer on the market certified by
the first IEC 61400-12-1 compliant classification.Low class numbers result in the lowestuncertainty attainable in both flat and complex
terrain, but can be further reduced by calculat-ing a site specific S-classification.
One-piece molded cup rotor contributes to anoutstanding low variability from unit to unitensuring consistent performance over the fullrange of influence parameters.Originally designed for marine environments,the P2546-OPR is the best choice on the marketfor wind resource assessment and powerperformance studies both offshore andonshore.

View Complete details

Yes! I am Interested Request a call back

HD52.3D Series 2 Axis Ultrasonic Anemometer

  • HD52.3D    Series 2 Axis Ultrasonic Anemometer
  • HD52.3D    Series 2 Axis Ultrasonic Anemometer
  • HD52.3D    Series 2 Axis Ultrasonic Anemometer
  • HD52.3D    Series 2 Axis Ultrasonic Anemometer
  • HD52.3D    Series 2 Axis Ultrasonic Anemometer
  • HD52.3D    Series 2 Axis Ultrasonic Anemometer
  • HD52.3D    Series 2 Axis Ultrasonic Anemometer
  • HD52.3D    Series 2 Axis Ultrasonic Anemometer
HD52.3D    Series 2 Axis Ultrasonic Anemometer
Get Best Quote
Price on Request

Product Brochure

Power supply10 to 30 Vdc
Power consumption26 mA @ 24 Vdc without heater 8 W @ 24 Vdc with heater
Operating temperature-40 to +70 C
Protection degreeIP66
CasePlastic material.

The instruments of the series HD52.3D… are 2 axes ultrasonic static anemometers for measuring

  • Wind speed and direction, U-V Cartesian components of wind speed
  • Wind Gust – Measurement available only with MODBUS-RTU and SDI-12 protocols
  • Relative Humidity and Temperature (optional),
  • Global Solar Radiation (optional)
  • Barometric pressure (optional)
  • Rainfall (optional)

The “Rainfall” and “Global solar radiation” options are alternatives (they can not be both present in the same instrument).

All models are equipped with a magnetic compass.

The avarage of wind speed and direction over a period configurable up to 10 mins is calculated.

RS232, RS485, RS422 and SDI-12 serial interfaces are available with NMEA, MODBUS-RTU and SDI-12 communication protocols. All versions have two analog outputs, both for wind speed and for direction, factory configurable among 4÷20mA (standard), 0÷1V, 0÷5V, 0÷10V (to be specified when ordering).

Advantages:

  • The absence of moving parts minimizes maintenance;
  • High sensitivity for detecting very low speeds, which are not detectable by traditional methods;
  • The low power of the instrument allows installation in remote sites, with power from solar panel and battery;
  • The heating option ‘R’ prevents the accumulation of snow and ice from forming, allowing accurate measurements in all environmental conditions;
  • Fast and easy installation, alignment facilitated by built-in compass;
  • The available measurement options join together in one single, compact and lightweight instrument, the main variables of interest in weather stations;
  • MODBUS-RTU output allows instrument networking.

View Complete details

Yes! I am Interested Request a call back

AEOLUS-3 3-Axis Ultrasonic Anemometer

  • AEOLUS-3 3-Axis Ultrasonic Anemometer
  • AEOLUS-3 3-Axis Ultrasonic Anemometer
  • AEOLUS-3 3-Axis Ultrasonic Anemometer
AEOLUS-3 3-Axis Ultrasonic Anemometer
Get Best Quote
Price on Request

Product Brochure

Instrument power supply12 to 30 vdc
Heating power supply24 Vdc
Measurement intervalFrom 1 to 4 Hz
Wind speed averaging intervalConfigurable from 1 s to 10 min
Operating temperature-40C to +70C
3-Axial ultrasonic anemometer with integrated heating and barometric pressure sensor. Robust housing for measurements also in the toughest conditions. Great flexibility in output choices: three analog outputs, as well as RS232, RS485, RS422 and SDI-12 isolated serial outputs for seamless integration with any system

View Complete details

Yes! I am Interested Request a call back

HD2003 3-Axis Ultrasonic Anemometer - Multiparameter

  • HD2003   3-Axis Ultrasonic Anemometer  - Multiparameter
  • HD2003   3-Axis Ultrasonic Anemometer  - Multiparameter
  • HD2003   3-Axis Ultrasonic Anemometer  - Multiparameter
HD2003   3-Axis Ultrasonic Anemometer  - Multiparameter
Get Best Quote
Price on Request

Product Brochure

Power Supply12 to 30 Vdc
Operating Conditions-40 to +60 DegreeC / 0 100% RH
Wind Speed0 to 70 m/s (252 km/h)
Sound Speed300 to 380 m/s
Pressure+- 0.4 mbar @ 20 DegreeC

HD2003 is a 3-axis static anemometer for measuring wind speed and direction, U-V-W cartesian components of speed, wind gust, sound speed, sonic temperature, air temperature, relative humidity and barometric pressure.

Main characteristics:

  • 5 analogue voltage or current outputs, with different measuring ranges.
  • RS232 and Multidrop RS485 Serial Communication interfaces.
  • Configurable output rate of digital output data string.
  • Configurable average periods 1÷60 s and 1÷60 min. for all output quantities.
  • Processing algorithms and validation of the raw measurement signals to provide a measure of greatness anemometer with ± 1%.
  • Digital high frequency data acquisition mode with 50Hz data output.
  • Self diagnostics with error checking and report.
  • Reliability and accuracy throughout the measuring range without further calibration.
  • Flexible, easy-to use demo software, configurable according to the user’s needs through Computer interface.
  • User interface for managing the setup and software upgrade via RS232 or RS485.
  • Compass magneto sensor for automatic alignment to magnetic north.
  • No moving parts, maintenance costs and reduced service.
  • Robust construction, suitable to operate continuously in harsh conditions.
  • Low power consumption.

Available as well with heating option (HD2003R): built-in heating device of sonic transducers, to prevent ice and snow formation. Assures correct measurements even in presence of sleet or snow.

View Complete details

Yes! I am Interested Request a call back

HD2003.1 - 3-Axis Ultrasonic Anemometer

  • HD2003.1 - 3-Axis Ultrasonic Anemometer
  • HD2003.1 - 3-Axis Ultrasonic Anemometer
  • HD2003.1 - 3-Axis Ultrasonic Anemometer
  • HD2003.1 - 3-Axis Ultrasonic Anemometer
HD2003.1 - 3-Axis Ultrasonic Anemometer
Get Best Quote
Price on Request

Product Brochure

Ultrasonic rate60Hz
Range0 / 70 m/s (252 km/h)
Accuracy+- 1% of reading
Humidity0% / 100% RH
Sensor TypePt100
Temperature Range-40 to +60 DegreeC

Please note that this code as well as the same version with heating option (HD2003.1R) have been discontinued.

Manual and datasheet are still available in the download tab.

The version with additional measurement of temperature, relative humidity and atmospheric pressure is still available. See product code HD2003.

If you are looking for our new 3 axis ultrasonic anemometer, please refer to the new AELOUS-3 series.

View Complete details

Yes! I am Interested Request a call back

HD2903T / HD29V3T - Active Air Speed Transmitters

  • HD2903T / HD29V3T - Active Air Speed Transmitters
  • HD2903T / HD29V3T - Active Air Speed Transmitters
  • HD2903T / HD29V3T - Active Air Speed Transmitters
  • HD2903T / HD29V3T - Active Air Speed Transmitters
  • HD2903T / HD29V3T - Active Air Speed Transmitters
  • HD2903T / HD29V3T - Active Air Speed Transmitters
HD2903T / HD29V3T - Active Air Speed Transmitters
Get Best Quote
Price on Request

Product Brochure

Brandsenseca
Accuracy+-1.5 %RH (10 to 90 %RH) +-2.0% RH (in the remaining range) for T= 15 to 35 DegreeC
Range0 to 100 %RH
Temperature accuracy+-0.3 DegreeC
Temperature measuring range-10 to +60 DegreeC
Storage temp.-10 to +70 DegreeC

The family of transmitters series HD29… are employed in the control of air speed in the air conditioning and ventilation (HVAC / BEMS) in the pharmaceutical, museum, clean rooms, ventilation ducts, industrial sectors and households, crowded places, cafeterias, auditoriums, gymnasiums or on farms with large numbers of animals.

The sensors in combination with an accurate electronics guarantee precise and reliable measurements in the time.

The sensor for the air speed is thin film, the probe sheath is AISI304, the filter relative humidity of 20μ wire mesh, materials that allow the use in hostile areas.

There are two possible installations: in the TO version, the horizontal probe is joined to the electronics enclosure while in the TC version the probe is conconnected to the electronics through a cable. In the TO version, the duct probe is fixed to the electronics enclosure and it is available in three different lengths. To fix the probe to the duct, you can use, for example, the HD9008.31 flange, a 3/8” universal biconical connection or a PG16 metal cable gland (∅10…14mm). In the TC version, the probe together with the sensors is equipped with a cable which can be 2, 5 or 10 meters long.

The probes are available in different lengths.

Possibilities of the several models:

– Air speed measurement with the HD2903T… and HD29V3T… series – analog output 4-20mA or 0-10VDC

– Air speed and Temperature measurement with the HD2937T… and HD29V37T… series – analog outputs 4-20mA or 0-10 Vdc

– Air speed, Humidity and Temperature measurement with the HD29371… series and HD29V371T – analog outputs 4-20mA or 0-10 Vdc

View Complete details

Yes! I am Interested Request a call back

05108-45 Wind Monitor HD-Alpine

05108-45 Wind Monitor HD-Alpine
Get Best Quote
Price on Request

Product Brochure

Model Name/Number05108-45
Range0 to 100 m/s (224 mph)
Operating Temperature-50 to 50 DegreeC (-58 to 122 DegreeF)
Sensor18 cm diameter 4-blade helicoid propeller
Pitch50.0 cm air passage per revolution
Distance Constant2.7 m (8.9 ft.) for 63% recovery
Threshold Sensitivity1.0 m/s (2.2 mph)
The reliability of the wind monitor sensor is well known. Thesensitive vane and propeller combination has proven effective forcountless applications in many disciplines.The Wind Monitor-HD Alpine combines the features of the HeavyDuty unit along with the ice-resistant coating of our popular AlpineWind Monitor. The HD utilizes extremely long-wearing, oversizeceramic bearings to increase service life of standard stainlesssteel bearings. Bearings have light contacting teflon seals andare filled with a low torque wide temperature range grease to helpexclude contamination and moisture. In addition to being morewear resistant, ceramic is resistant to corrosion in the most hostileenvironments.The Wind Monitor-HD Alpine also has an oversized propellershaft , high pitch propeller, and a locking propeller nut. The mainhousing, nose cone, propeller, and other internal parts are injectionmolded U.V. Stabilized plastic. All external housing surfacesare coated with a specially formulated, ice-resistant coating toimprove performance in harsh alpine conditions. Both the propellerand vertical shafts use ceramic ball bearings. Bearings havelight contacting teflon seals and are filled with a low torque widetemperature range grease to help exclude contamination andmoisture.Propeller rotation produces an AC sine wave signal with frequencyproportional to wind speed. This AC signal is induced in astationary coil by a six pole magnet mounted on the propeller shaft.Three complete sine wave cycles are produced for each propellerrevolution.Vane position is transmitted by a 10K ohm precision conductiveplastic potentiometer which requires a regulated excitation voltage.With a constant voltage applied to the potentiometer, the outputsignal is an analog voltage directly proportional to azimuth angle.The instrument mounts on standard one inch pipe, outsidediameter 34 mm (1.34"). An orientation ring is provided so theinstrument can be removed for maintenance and reinstalled withoutloss of wind direction reference. Both mounting post assembly andorientation ring are secured to the mounting pipe by stainless steelband clamps. A 3 meter (9.8 ft) pigtail cable assembly is suppliedfor electrical connections. For longer cable lengths a user suppliedjunction box or connector may be used. A variety of devices areavailable for signal conditioning, display, and recording of windspeed and direction.

View Complete details

Yes! I am Interested Request a call back
HD51.3D   High Performance Two Axes Ultrasonic Anemometer

HD51.3D High Performance Two Axes Ultrasonic Anemometer

Price on Request
Get Best Quote Request a call back

EXPLORE MORE CATEGORIES