HD51.3D High Performance Two Axes Ultrasonic Anemometer

  • HD51.3D   High Performance Two Axes Ultrasonic Anemometer
  • HD51.3D   High Performance Two Axes Ultrasonic Anemometer
  • HD51.3D   High Performance Two Axes Ultrasonic Anemometer
  • HD51.3D   High Performance Two Axes Ultrasonic Anemometer
  • HD51.3D   High Performance Two Axes Ultrasonic Anemometer
  • HD51.3D   High Performance Two Axes Ultrasonic Anemometer
  • HD51.3D   High Performance Two Axes Ultrasonic Anemometer
  • HD51.3D   High Performance Two Axes Ultrasonic Anemometer
HD51.3D   High Performance Two Axes Ultrasonic Anemometer
Get Best Quote
Price on Request

Product Brochure

Power supply12 to 30 Vdc
Power consumption60 mA at 24 Vdc
Measurement intervalfrom 250 ms to 1 s
Operating temperature-40 to +70 C -50 to +70 C
HousingASA with aluminum and AISI 316 metal parts anodized aluminum alloy and AISI 316

HD51.3D… is a series of high performance two-axis static ultrasonic anemometers for accurate measurements in all environmental conditions.

Available in different combinations for the measurement of:

  • Wind speed (up to 85 m/s)
  • Wind direction
  • Cartesian U-V components of wind speed
  • Wind Gust
  • relative humidity and temperature (optional)
  • global solar radiation (optional)
  • atmospheric pressure (optional).

View Complete details

Yes! I am Interested Request a call back

BAROsense - Barometric Pressure Transmitters

  • BAROsense - Barometric Pressure Transmitters
  • BAROsense - Barometric Pressure Transmitters
  • BAROsense - Barometric Pressure Transmitters
  • BAROsense - Barometric Pressure Transmitters
BAROsense - Barometric Pressure Transmitters
Get Best Quote
Price on Request

Product Brochure

Accuracy+- 0.5 hPa (700 to 1100 hPa) @ 20 DegreeC
Measuring range300 to 1100 hPa
Weight250 g approx.
Operating conditions-40 to +60 DegreeC
Power supplyBAROsense-M: 7 to 30 Vdc BAROsense-1 and BAROsense-5: 8 to 30 Vdc BAROsense-10: 15 to 30 Vdc

Please note that this product has been discontinued.

Kindly refer to:

  • PBS83M… series for barometric transmitters with digital output
  • PBS860… and PBS880… for barometric transmitters with analog output.

View Complete details

Yes! I am Interested Request a call back

LPUVI02 Series - UV Index Radiometric Probes

  • LPUVI02  Series - UV Index Radiometric Probes
  • LPUVI02  Series - UV Index Radiometric Probes
  • LPUVI02  Series - UV Index Radiometric Probes
LPUVI02  Series - UV Index Radiometric Probes
Get Best Quote
Price on Request

Product Brochure

Usage/ApplicationIndustrial
BrandSenseca
Model Name/NumberRadiometro UV Index LPUVI02
ColorWhite
Measuring range0 to 16 UV Index (LPUVI02AV...) 0 to 20 UV Index (LPUVI02.1AV....)
Power supply8 to 30 Vdc

The radiometer LPUVI02 measures the global effective irradiance on a flat surface (Watt /m² effective), according to the requirements of the WMO for the measurement of UV-index.

The global irradiance is the sum of direct sun and of diffuse irradiance. In the ultraviolet spectral region, unlike what occurs in the portion of the visible light where the direct component is prevalent on the diffuse component, the light is strongly scattered in the atmosphere, and then the two components are equal; it is therefore of primary importance that the radiometer is able to accurately measure both components.

The radiometer LPUVI02 is produced with voltage output:

  • LPUVI02AV –  0…1 Vdc, 0…5 Vdc or 0…10 Vdc output  (0…16 UV index) to be defined when ordering.
  • LPUVI02.1AV – 0…1V dc, 0…5 Vdc or 0…10 Vdc output (0…20 UV index) to be defined when ordering.

The versions 02.1 have a full scale that reach 20 UV-index and are suitable for the measurement of UV in equatorial areas and high mountain: in these places in fact  index value UV of 11 can be exceeded for a significant time.
The power supplied is required at 8-30 Vdc, except for the version LPUVI02AV10 (voltage output 0-10 V) which is of 15-30 Vdc.

The instrument is managed to operate for long periods without maintenance (except cleaning of the dome and checking the status of silica gel) provided that it is properly powered.

This feature makes the device ideal for use in remote weather stations also.

View Complete details

Yes! I am Interested Request a call back

LPUVA02 - Radiometric Probe for Irradiance

  • LPUVA02 - Radiometric Probe for Irradiance
  • LPUVA02 - Radiometric Probe for Irradiance
  • LPUVA02 - Radiometric Probe for Irradiance
  • LPUVA02 - Radiometric Probe for Irradiance
  • LPUVA02 - Radiometric Probe for Irradiance
  • LPUVA02 - Radiometric Probe for Irradiance
  • LPUVA02 - Radiometric Probe for Irradiance
  • LPUVA02 - Radiometric Probe for Irradiance
  • LPUVA02 - Radiometric Probe for Irradiance
  • LPUVA02 - Radiometric Probe for Irradiance
  • LPUVA02 - Radiometric Probe for Irradiance
  • LPUVA02 - Radiometric Probe for Irradiance
LPUVA02 - Radiometric Probe for Irradiance
Get Best Quote
Price on Request

Product Brochure

BrandSenseca
Model Name/NumberUVA Radiometer LPUVA02
ColorWhite
Measuring range0 to 200 W/m2
Response time<0.5 s (95%)

Radiometric probe for outdoor use for measuring IRRADIANCE in the UVA spectral range (315…400 nm).  Supplied with Calibration Report. On request CPM12AA4… cables with 4-pole M12 connector.

The LPUVA02 radiometer measures the broadband UVA irradiance on a plane surface (Watt/ m²). Measured irradiance is the result of the sum of direct solar
irradiance and of diffuse irradiance. TIt can measure as well the UVA irradiance in closed room.

The radiometer is produced in three versions:

  • LPUVA02 – passive – μV per μW/cm² output;
  • LPUVA02AC – active, 4…20 mA current output (0…150 W/m²), integrated transmitter amplifier.
  • LPUVA02AV – active, 0…1Vdc, 0…5Vdc or 0…10Vdc output (0…150 W/m²) to be defined when ordering, integrated transmitter amplifier.

View Complete details

Yes! I am Interested Request a call back

HD32.35 - Housing with Acquisition System for Weather Stations

  • HD32.35 - Housing with Acquisition System for Weather Stations
  • HD32.35 - Housing with Acquisition System for Weather Stations
HD32.35 - Housing with Acquisition System for Weather Stations
Get Best Quote
Price on Request

Product Brochure

ColorPowder-coated anodized aluminium, white colour
MaterialAISI 304 stainless steel.
ProtectionIP66
Dimensions450 x 300 x 210 mm.
Power Supply100 / 240Vac

HD32MT.1 data logger integrated in an AISI 304 stainless steel outdoor housing. Screen to protect the housing from solar radiation. Powder-coated white.

Double locking, one is a key. Dimensions 450 x 300 x 210 mm. IP66 protection degree.

Supplied with accessories for attachment to the pole diameter 36…52 mm. Provided for 100…240 Vac mains power supply or for power supply from solar panel (version HD32.35FP). Wired and tested.

Optionally, LCD viewer simple (HD32.3D) or with GPS module for automatical time synchronization of the data logger (HD32.D.GPS)

View Complete details

Yes! I am Interested Request a call back

PMsense - Particulate Matter Transmitter

  • PMsense - Particulate Matter Transmitter
  • PMsense - Particulate Matter Transmitter
  • PMsense - Particulate Matter Transmitter
  • PMsense - Particulate Matter Transmitter
  • PMsense - Particulate Matter Transmitter
PMsense - Particulate Matter Transmitter
Get Best Quote
Price on Request

Product Brochure

BrandSenseca
Measuring principleDouble wavelength NDIR
Measuring range0 to 5000 ppm
Response time< 120 s (air speed= 2 m/s)
ConnectionM12 8-pole circular connector

PMsense is a PM1.0PM2.5 and PM10 Particulate Matter transmitter with RS485 Modbus-RTU output, suitable for outdoor air quality monitoring.

The dust particles concentration is measured using the laser scattering principle.

The transmitter is maintenance-free and has fast response, high sensitivity and an excellent stability.

The PM sensor can be operated in two ways:

  • Continuous operating mode: the sensor is always active and measurements are continuously taken. In this mode at least 10,000 hours of PM sensor life are guaranteed.
  • Discontinuous operating mode (default): the sensor is activated at regular intervals, when measurements has to be taken. This mode increases the PM sensor life.

On request, an optional CO2 sensor can be integrated in the trasmitter.

The transmitter can be supplied with up to 2 optional configurable 4…20 mA, 0…5 V or 0…10 V analog outputs.

More background information on why to measure Particulate Matter (PM) can be found here.

View Complete details

Yes! I am Interested Request a call back

HD50CR - Clean Room Logger Transmitter

  • HD50CR - Clean Room Logger Transmitter
  • HD50CR - Clean Room Logger Transmitter
  • HD50CR - Clean Room Logger Transmitter
  • HD50CR - Clean Room Logger Transmitter
  • HD50CR - Clean Room Logger Transmitter
HD50CR - Clean Room Logger Transmitter
Get Best Quote
Price on Request

Product Brochure

Usage/ApplicationPharmaceutical industry
BrandDelta OHM
MaterialStainless steel
Model Name/NumberHD50CR
AlarmBuzzer, LED, E-mails
RS485Modbus-RTU Slave
Power supply24 Vac / Vdc +-10% (Max 5 W)

The HD50CR is the ideal solution for monitoring of differential pressure, temperature and humidity in Clean Room applications.

low pressure sensor with high accuracy and stability and auto-zeroing feature ensure high accuracy and stability over the time.

Three 0…5/10 V and 0/4…20 mA analog outputs and a digital RS485 output with “Slave” Modbus-RTU protocol allow connecting the instrument to a network of sensors are available. The instrument can also be connected to a local network via the Ethernet interface (optionally Wi-Fi, on request). The simultaneous operation of two communication protocols (proprietary and Modbus TCP/IP) is possible. The instrument manages up to 10 “TCP/IP Client” simultaneously. If the local network is connected to Internet, the data can be regularly sent to an FTP address, to the Cloud and via e-mail.

The instrument is also available in a version with only the 3 analogue outputs and the RS485 digital output, with decimal resolution. Click here for the HD50CR-AS dedicated manual.

Configuring the instrument is very simple: if both connected to the same network, this can be done through any device that has been granted access to the instruments webserver.

For each detected quantity, two alarm thresholds can be set by the user. Exceeding a threshold is signaled by direct alarms.

For specific FDA regulations that can apply in the Pharmaceutical industry, we can provide optional modules to our standard HD35AP-S and HDServer1 software to fully operate conform 21 CFR part 11 regulations.

The HD50CR provides the ideal solution for the application, keeping track of any out of range values and providing the perfect evidence for any quality audit. The stainless steel flush-mounted style guarantees that the instrument is easy to clean.

View Complete details

Yes! I am Interested Request a call back

HD3910... - Soil Volumetric Water Content

  • HD3910... -  Soil Volumetric Water Content
  • HD3910... -  Soil Volumetric Water Content
  • HD3910... -  Soil Volumetric Water Content
  • HD3910... -  Soil Volumetric Water Content
HD3910... -  Soil Volumetric Water Content
Get Best Quote
Price on Request

Product Brochure

Model Name/NumberHD3910... series
Resolution0.1%
Protection degreeIP 67
Measuring range0 to 60% VWC
Sensor operating temperature-40 to +60 DegreeC

The probes HD3910.1 (two electrodes) and HD3910.2 (three electrodes) measure the soil volumetric water content (VWC) by using a capacitive measurement principle which allows fast measurements in the field and with minimal invasiveness.

The three electrode probe HD3910.2 is particularly suitable for the measurement in small volumes, for example for cultivations in pots.

The probes give a direct reading in Volumetric Water Content (VWC) from 0-60%.

Versions available:

  • RS485 digital output with MODBUS-RTU protocol: allows the use of even very long connection cables. It can be connected to the data loggers HD32MT.1 and HD32MT.3 or to any other data logger with RS485 MODBUS-RTU input.
  • SDI-12 digital output is compatible with version 1.3 of the protocol and can be connected to the data logger HD32MT.3 or to any other data logger with SDI-12 input.
  • Analog output has two 0.5…3 V standard voltage outputs: one for the volumetric water content and one for the temperature. On request, 0…2.5 V, 0…5 V or 0…10 V outputs.

The probes are equipped with a fixed cable, 5 or 10 m standard length, with open wires at the end.

View Complete details

Yes! I am Interested Request a call back

HD2021T6 / HD2021T7 - Photometric Radiometric Transmitters

  • HD2021T6 / HD2021T7 - Photometric Radiometric Transmitters
  • HD2021T6 / HD2021T7 - Photometric Radiometric Transmitters
  • HD2021T6 / HD2021T7 - Photometric Radiometric Transmitters
  • HD2021T6 / HD2021T7 - Photometric Radiometric Transmitters
  • HD2021T6 / HD2021T7 - Photometric Radiometric Transmitters
HD2021T6 / HD2021T7 - Photometric Radiometric Transmitters
Get Best Quote
Price on Request

Product Brochure

Dimensions148.5 mm x 60 mm x 66 mm
Working Temperature-20 Degree to +60 Degree C
Voltage0...10V
Output4…20 mA
Power supply16...40 vdc

The transmitters allow converting the photometric quantity “equivalent veiling luminance” – HD2021T7 – or a photometric quantity Luminance (cd/m2) – HD2021T6 – into a current (4…20 mA) or a voltage (0…10 V) signal according to the version chosen. If the acquisition station is far from the probe (>50m), it is necessary to use the current output version.The probe is used for the control of street lighting, in particular, the measurement of equivalent veiling luminance is essential to determine the threshold luminance at the entrance of the tunnels (UNI 11095:2011).

HD2021T7 is used for the control of street lighting, in particular, the measurement of equivalent veiling luminance is essential to determine the threshold luminance at the entrance of the tunnels (UNI 11095:2011).  The transmitter full scale can be chosen (when ordering) between two different values:  2000 cd/m2 or 20000 cd/m2

HD2021T6 is used for road lighting control. In particular, the measurement of luminance at a 20° angle (L20) is necessary to estimate threshold luminance at tunnel entrances (CIE standard 88:2004. This standard foresees the measurement of debilitating luminance in future). Moreover, the probe can be used for calculating vertical illuminance (Ev) as prescribed in the above-mentioned standard. At the order time, it is possible to choose the transmitter sensitivity among three previously set values: 2 kcd/m², 20 kcd/m² or 200 kcd/m².  Finally, the probe can be used for any application where the measurement of luminance is required, for example projector screens, diaphanoscopes etc.

View Complete details

Yes! I am Interested Request a call back

LPPHOT03... Series - Photometric Probes for Illuminance

  • LPPHOT03... Series - Photometric Probes for Illuminance
  • LPPHOT03... Series - Photometric Probes for Illuminance
  • LPPHOT03... Series - Photometric Probes for Illuminance
  • LPPHOT03... Series - Photometric Probes for Illuminance
  • LPPHOT03... Series - Photometric Probes for Illuminance
  • LPPHOT03... Series - Photometric Probes for Illuminance
LPPHOT03... Series - Photometric Probes for Illuminance
Get Best Quote
Price on Request

Product Brochure

Typical sensitivity0.5 to 1.5 mV/(klux)
Operating temperature-20 DegreeC to +60 DegreeC
Version with RS485 MODBUS-RTU output0 to 200 klux
Calibration uncertainty< 4%
Version with RS485 MODBUS-RTU output0...200 klux
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.

Calibration is carried out by comparison with a reference luxmeter, calibrated by a Primary Metrological Laboratory. The Calibration Procedure complies with the CEI publication No.69 “Methods of characterizing illuminance meters and luminance meters: Performance characteristics and specifications, 1987”.

The photometric measurement probe is designed for outdoor readings. CIE photopic filter.

Output, according to the chosen configuration, in mV or 4…20 mA or 0…10 Vdc normalized output or RS485 MODBUS-RTU output.

  • LPPHOT03 = mV / klux
  • LPPHOT03BL = mV / klux output + base with levelling device
  • LPPHOT03BLAC = output 4…20 mA + base with levelling device
  • LPPHOT03BLAV = output 0…10 V + base with levelling device
  • LPPHOT03BLS = RS485 MODBUS-RTU output + base with levelling device

Working temperature -20…+60 °C.  M12 male 4-pole (models with analog output) or 8-pole (model with RS485 MODBUS-RTU output) connector.

On request CPM12AA4… (except LPPHOT03BLS) or CPM12-8D (only LPPHOT03BLS) cable with M12 female connector.

View Complete details

Yes! I am Interested Request a call back

HD32.36 - Outdoor Housing with Acquisition System

  • HD32.36 - Outdoor Housing with Acquisition System
  • HD32.36 - Outdoor Housing with Acquisition System
  • HD32.36 - Outdoor Housing with Acquisition System
HD32.36 - Outdoor Housing with Acquisition System
Get Best Quote
Price on Request

Product Brochure

MaterialPolyester reinforced with hot-moulding Fiberglass.
BrandDelta OHM
IP GradeIP66
Power Supply100 / 240Vac
Dimensions415 x 310 x 170 mm

HD32MT.1 data logger integrated in a fiberglass-reinforced hot-pressed polyester outdoor housing. Screen to protect the housing from solar radiation, powder-coated anodized aluminum. White.

Key lock. Dimensions 415 x 310 x 170 mm. IP66 protection degree.

Supplied with accessories for attachment to the stainless steel pole diameter 36…52 mm. Provided for 100…240 Vac mains power supply or for power supply from solar panel (version HD32.36FP). Wired and tested.

Optionally, LCD viewer simple (HD32.3D) or with GPS module for automatical time synchronization of the data logger (HD32.D.GPS)

View Complete details

Yes! I am Interested Request a call back

HD53GSM - GSM/GPRS Module

  • HD53GSM - GSM/GPRS Module
  • HD53GSM - GSM/GPRS Module
HD53GSM - GSM/GPRS Module
Get Best Quote
Price on Request

Product Brochure

Interface TypeRS232, SubD 9pin connector
Usage/ApplicationIndustrial
Model Name/NumberHD 53GSM QUAD-BAND GSM/GPRS MODULE
Frequency band (MHz)GSM850, GSM900, DCS1800, PCS1900
Power supply8 to 28Vdc
Operating temperature- 35 to +80 DegreeC

HD53GSM is a wireless quad-band GSM/GPRS modem. The module is controlled via standard RS232 serial interface and AT commands.

It features:

  • SIM card slot,
  • SMA antenna connector,
  • power line connector with remote on/off line,
  • two status LED: the POWER LED is switched on when the GSM is powered, the NET LED indicates the connection status to the GSM net,
  • RS232 Sub-D 9-pin connector.

View Complete details

Yes! I am Interested Request a call back

Pitot Tubes

  • Pitot Tubes
  • Pitot Tubes
  • Pitot Tubes
  • Pitot Tubes
Pitot Tubes
Get Best Quote
Price on Request

Product Brochure

BrandDelta OHM

Stainless steel Pitot tubes to measure air speed and temperature, for models provided with ‘K’ thermocouple, equipped with silicon tube with 6 mm external diam., 4 mm internal diam. and length 2 m.

PW cable has to be ordered separately.

Types available:

T1-300 – lenght 300 mm

T2-400 – lenght 400 mm

T3-800 – lenght 800 mm

T3-800TC -lenght 800 mm – K thermocouple

For other lengths please, contact us.

View Complete details

Yes! I am Interested Request a call back

VUP12 - Heating and Ventilation Unit

  • VUP12 - Heating and Ventilation Unit
  • VUP12 - Heating and Ventilation Unit
  • VUP12 - Heating and Ventilation Unit
  • VUP12 - Heating and Ventilation Unit
  • VUP12 - Heating and Ventilation Unit
VUP12 - Heating and Ventilation Unit
Get Best Quote
Price on Request

Product Brochure

MaterialStainless Steel
Usage/ApplicationIndustrial
Ventilation power supply12 Vdc +- 10% / 1.6 W
Heating power supply12 Vdc +- 10%
Operating conditions-40 to +70 DegreeC
Connection8-pole M12 connector

The VUP12 ventilation and heating unit allows increasing the accuracy of solar radiation measurements maintaining the operating temperature of the sensor uniform. Ventilation reduces the type “A” offset (present in pyranometers and pyrgeometers) due to cooling of the dome with respect to the sensor body.

It can be used outdoor in any weather condition and avoids the formation of dew and frost on the optical part of the sensor.

The use of ventilation and moderate heating prevents dew formation on the dome, especially in the early morning hours, allowing much more accurate measurements even in moderate climates. The heating function can also be used in extreme environmental conditions, to avoid the formation of snow and ice on the sensor dome.
The unit is equipped with two independent heating circuits of equal power, which can be individually activated to better adapt the heating function to the climate of the installation site.

The unit is suitable for LPS02… and LPS10… series pyranometers and allows solar radiation measurements to be performed according to the recommendations of the following standards:

  • IEC 61724-1
  • ISO/TR 990
  • “BSRN operations manual”

View Complete details

Yes! I am Interested Request a call back

LPPHOT02 - Photometric Probe for Illuminance

  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
  • LPPHOT02 - Photometric Probe for Illuminance
LPPHOT02 - Photometric Probe for Illuminance
Get Best Quote
Price on Request

Product Brochure

ColorWhite
Measuring range0 to 150 klux
Typical sensitivity0.5 to 2 mV/klux
Spectral rangeStandard photopic curve
Power supply10 to 30 Vdc
Operating temperature-40 DegreeC to +80 DegreeC

Outdoor photometric probe for measuring ILLUMINANCE (0…150 Klux), CIE photopic filter, diffuser for cosine correction. mVdc output for klux. Complete with Calibration Report. On request 5 or 10m cables with connectors.

LPPHOT02… probe measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²).
The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT02 and the standard photopic curve V(λ) is calculated by means of the error f1′.

LPPHOT02 is designed and constructed for outdoor installation for long periods. The photometric measurement for external use is used for the measurement of daylight in climatological and meteorological applications.

The luxmeter is produced in three versions:

  • LPPHOT02 – passive (mVdc output for klux);
  • LPPHOT02AC – active (4…20 mA output, integrated transmitter amplifier);
  • LPPHOT02AV – active (0…1Vdc, 0…5Vdc or 0…10Vdc output to be defined when ordering, integrated transmitter amplifier)

View Complete details

Yes! I am Interested Request a call back

LPNET14 - 4-Component Net-Radiometer

  • LPNET14 - 4-Component Net-Radiometer
  • LPNET14 - 4-Component Net-Radiometer
  • LPNET14 - 4-Component Net-Radiometer
LPNET14 - 4-Component Net-Radiometer
Get Best Quote
Price on Request

Product Brochure

Model Name/NumberNet-Radiometer LPNET14
BrandSenseca
Measuring range0 to 2000 W/m2
Spectral range300 nm to 2800 nm (50%)
Viewing angle160 Degree

LPNET14 is a 4-component net-radiometer for the measurement of the net radiation between 0.3 μm and 45 μm.

The net-radiometer consists of two pyranometers (one for the measurement of the global radiation Esw↓ and the other one for the measurement of the reflected solar radiation Esw↑ ) and a pair of pyrgeometers (one for the measurement of the infrared radiation emitted by the sky EFIR↓ and the other one for the infrared emitted by the ground surface EFIR↑).

The LPNET14 is equipped with a temperature sensor (NTC). The measurement of the temperature is needed for the measurement with the two pyrgeometers, in fact, the far infrared is derived by measuring the thermopile output and by the knowledge of the instrument’s temperature.

The net radiometer is suitable for outdoor use in all weather conditions and requires little maintenance.

View Complete details

Yes! I am Interested Request a call back

HD9906.51 - Ventilation and Heating Unit

  • HD9906.51 - Ventilation and Heating Unit
  • HD9906.51 - Ventilation and Heating Unit
  • HD9906.51 - Ventilation and Heating Unit
HD9906.51 - Ventilation and Heating Unit
Get Best Quote
Price on Request

Product Brochure

MaterialStainless Steel
Ventilation power supply12 Vdc +- 10% / 5 W
Heating power supply12 Vdc +- 10% / 7 W
Operating conditions-30 DegreeC to +70 DegreeC / 0 to 100 %RH Max. altitude 3000 m
Cable length5 m standard

The heating and ventilation unit is meant to be used with solar radiation sensors (pyranometer, pyrgeometer and radiometer) and can be used outdoor under any weather conditions.

The ventilation of the instruments increases the precision of the measures by making the pyranometer’s temperature uniform, in particular it avoids the deposit of dew and frost on the optical parts of the sensors and reduces the off-set of type A (present in pyranometers and pyrgeometers) caused by the cooling of the dome with respect to the instrument’s body.

The HD9906.51 unit can be used with LPPYRA02 and LPPYRA10, with the pyrgeometer LPPIRG01 and the radiometers LPPHOT02, LPUVA02 and LPUVB02.

View Complete details